UPS Energy Storage System

The Application scenario of the communication base station backup power supply is the outdoor communication base station and the IDC machine room. In the aspect of communication base station, there are many different products, like 48100, 4810 and 4875. And its working pattern is different. The competitive edges are that small size, high voltage and big capacity--better traditional lead-acid battery replacement choice, standard server size that can be built-in 19-inch rack--save room, wide operating temperature range, long service life and independent development and production of single cells--make sure consistency performance of cells.  

INQUIRY NOW

Parameters of UPS Energy Storage System

No.ItemSPEC.
48100
1Capacity/kWh4.8kWh
2Rated Voltage/V48
3MaterialLFP
4Standard Discharge Current/A0.2C
5Max. Continuous Discharge Current1C
6Standard Charge Current0.2C
7Max. Continuous Charge Current1C
8Cycle Life≥1500
9Communication ModeRS232,RS485
10Operating Temperature RangeCharge0-45℃
Discharge-20-60℃
11Applicable StandardUL, IEC62619, UN38.3



No.ItemSPEC.
1Module Specifications12S2P (0.5C)8S3P (0.3C)
2Rack Series And Parallel180S2P (15 modules+1 high-pressure box)184S3P (23 modules+1 high-pressure box)
3System Series And Parallel180S12P (6 racks parallel)184S12P (4 racks parallel)
4Rated Capacity300Ah/1800Ah450Ah/1800Ah
5Rated VoltageDC576VDC588.8V
4Working Voltage Range450V~657V460V~671.6V
5Operating Voltage Range522V~639V533.6V~653.2V
6Rack Rated Energy172.8KWh264.96KWh
7System Rated Energy1036.8KWh1059KWh


UPS Battery Competitive Edges

The application area is the outdoor communication base station and the IDC machine room. And there are four working patterns, that is pattern 1 normal electric supply, pattern 2 overrun electric supply voltage, and frequency, pattern 3 out of electric supply, and pattern 4 UPS system fault. The 48100 Backup Power of Communication Base Station whose cycle life is over 2000 times.

Small size, high voltage, and big capacity--better traditional lead-acid battery replacement choice.

Standard server size that can be built-in 19-inch rack--save room.

Wide operating temperature range.

Long service life.

Independent development and production of single cells--make sure consistency performance of cells.


ups battery competitive edges
ups battery pack competitive edges
ups power backup competitive edges

Get In Touch With Your Lithium Battery Supplier-Great Power

Reach Out to Great Power

We Want To Hear From You

Curious about lithium batteries technology? Need help selecting the right battery? Call us toll-free or use the form to let us know how we can help and we'll be in touch with you promptly.


Related Lithium Batteries Blogs about Great Power
Contact Us
912 Shiliang Rd (Xicun Section), Shawan,
Panyu, Guangzhou, China
sales@greatpower.net
020 3919 6888
follow us